=== Depots ===
=== Depots ===


We are evaluating a new depot configuration with one 4-core Intel I7, 12 GB of RAM, two 1 Gb network ports, and 24 TB of storage space.  This depot may optionally connect to the network via 10 Gb ethernet (via an add-on adapter).  We will provide power requirements for this box at a later date.
We are evaluating a new depot configuration a 2U server, with one 4-core Intel I7, 12 GB of RAM, two 1 Gb network ports, and 24 TB of storage space.  This depot may optionally connect to the network via 10 Gb ethernet (via an add-on adapter).  We will provide power requirements for this box at a later date.  You need to tell us if you site uses 110 or 220V power.


=== IP Addresses ===
=== IP Addresses ===

Revision as of 10:15, 31 March 2010

Depots

We are evaluating a new depot configuration a 2U server, with one 4-core Intel I7, 12 GB of RAM, two 1 Gb network ports, and 24 TB of storage space. This depot may optionally connect to the network via 10 Gb ethernet (via an add-on adapter). We will provide power requirements for this box at a later date. You need to tell us if you site uses 110 or 220V power.

IP Addresses

We require two externally-visible IP address for each depot. One address is for the depot itself, the other is for the management console.

Network Ports on your Switch

We support three types of network connectivity for data traffic:

  • Preferably,the depot can connect via 10 Gb ethernet for those sites that can use it. This requires your primary switch to have a 10 Gb optical port and a fiber cable long enough to stretch between depot and switch. Please let us know what type of optics you require, as well as if you need fiber.
  • Each depot has two network interfaces, so if supported by your switch, we can use both interfaces in 802.3ad bonding mode for increased performance. This requires two switch ports and two ethernet cables per depot.
  • Otherwise, the depot will use one of its 1 Gb network ports (requires one switch port/cable per depot).

In addition, each depot has an ethernet port for the management console. The management consoles can connect directly to your primary network switch, or they can run off a smaller dumb switch to minimize the number of primary switch ports in use.

Required Network Ports

These ports should be opened on your perimeter firewall (or firewalls if you have both organizational and departmental firewalls).

  • Management interface:
Port Service Notes
tcp/22 ssh from all depots to 129.59.197.90
tcp/80 www from all depots to 129.59.0.0/16
tcp/443 https from all depots to 129.59.0.0/16
tcp/5900 and 5901 vnc from all depots to 129.59.0.0/16


  • Depot network interface:
Port Service Notes
tcp/22 ssh from all depots to 129.59.197.60 and 129.59.197.90
tcp/5666 nagios from all depots to 129.59.197.60 and 129.59.197.90
tcp/6714 ibp from all depots to world
tcp/4823 bwctl from all depots to world
tcp/861 owamp from all depots to world
udp/123 ntp allow outbound from local depots
udp/161 snmpv3 from all to 129.59.197.60 and 129.59.197.90